UPT Perpustakaan Universitas Andalas
Repositori PerpustakaanUniversitas Andalas
 

Simulation Of Electron Dose Distribution For Dragon Fruit Phytosanitary Using Ellipsoid Model With Particle And Heavy Ion Transport Code System

dc.contributor.authorIbrahim, Ibrahim
dc.date.accessioned2026-09-24T19:05:50Z
dc.date.issued2026-01-26
dc.descriptionDr. Afdhal Muttaqin, M. Si
dc.description.abstractThis study aims to develop a Monte Carlo simulation model using the Particle and Heavy Ion Transport Code System (PHITS) to analyze the distribution of 10 MeV electron doses in a dragon fruit ellipsoid model and to validate the accuracy of dose predictions by comparing specific positions, specifically top, middle, and bottom, as well as statistical evaluation of experimental data. Simulations were performed on nine variations of dragon fruit sizes with combination of three vertical diameters, consisting of (7.0, 7.4, 7.7) cm, and three mass ranges (300, 350, 400) g in two-sided irradiation configuration. The scanning horn model was validated using Riso Aluminum Wedge experimental data with mean deviation is 2.55%. The simulation results showed that two-sided irradiation produced uniform dose distribution with a Dose Uniformity Ratio (DUR) value ranging from 1.15 to 1.32. All DUR values were below the maximum limit of 2.5 set by ISO/ASTM 51649 for phytosanitary processes, thus meeting the required dose uniformity criteria. The average Dmin 380.97 ± 12.22 approximated the 400 Gy generic phytosanitary threshold recommended for Bactrocera dorsalis inactivation, while the average Dmax 470.34 ± 8.99 Gy is below the fruit quality degradation threshold. Comprehensive statistical validation was performed, including Bland-Altman analysis, paired t-tests, and relative deviation calculations. The results showed good agreement between the simulation and experimental measurements using alanine dosimeters at the geometric center with average relative deviation of 10.52% (p=0.1513). However, at the top and bottom surface positions, systematic bias in the form of dose underestimation (30-34) % (p<0.001) was found, caused by the assumption of material homogeneity that did not capture the backscattering effect of electrons at the interface between the air and the fruit tissue.
dc.identifier.urihttps://ailib.my.id/handle/123456789/21768
dc.language.isoid
dc.publisherUniversitas Andalas
dc.subjectdragon fruit
dc.subjectdose distribution
dc.subjectDUR
dc.subjectphytosanitary
dc.subjectPHITS
dc.subject.classificationQC Physics
dc.titleSimulation Of Electron Dose Distribution For Dragon Fruit Phytosanitary Using Ellipsoid Model With Particle And Heavy Ion Transport Code System
dc.typeThesis
dcterms.dateSubmitted2026-04-20
dcterms.referencesAlexander, S.A., 2024, Impact of Phytosanitary Irradiation on Polar Antioxidants in Peels of ‘Granny Smith’ Apples, Thesis, Schmid College of Science and Technology, Chapman University, Orange, California. Aryanta, I.W.R., 2022, Manfaat Buah Naga Untuk Kesehatan, E-Jurnal Widya Kesehatan, Vol. 4 (2). Attix, F.H., 2004, Introduction to Radiological Physics and Radiation Dosimetry, WILEY-VCH verlag GmbH & Co. KGaA, Madison, Wisconsin. Bland, J.M., Altman, D., 1986, Statistical Methods for Assessing Agreement Between Two Methods Of Clinical Measurement, The Lancet, Vol. 327, Pp. 307–310, DOI:10.1016/S0140-6736(86)90837-8. BPS, 2025, Buletin Statistik Perdagangan Luar Negeri: Ekspor menurut HS, Desember 2024, Badan Statistik. https://www.bps.go.id/id/publication/2025/02/28/940d4b1b63231ab02ae0a0 31/buletin-statistik-perdagangan-luar-negeri-ekspor-menurut-hs--desember 2024.html (Accesses at 8-Agustus-2024) BRIN, 2025, Hasil Uji Terap Dosimeter Alanine [Unpublished raw data], Badan Riset dan Inovasi Nasional, Indonesia. Pusat Cao, V.C., Vo, A.T., Le, Q.T., Le, N.T., Duong, T.H., Tran, H.-N., 2021, Depth dose profiles in continuous and discontinuous materials of food products and medical devices irradiated by 10 MeV electron beam, Journal of Radioanalytical and Nuclear Chemistry, Vol. 330, Pp. 609–617, DOI:10.1007/s10967-021-07985-5. Firmansyah, O.A., Kurniawan, B., Saputro, B., Walo, M., Gryczka, U., Nuraeni, N., 2025, A Review of Emerging Trends in Experimental, Simulation, and Theoretical Methods for Dose Calculation in Radiation Processing, Nukleonika, Vol. 70 (3), Pp. 59–77, DOI:10.2478/nuka-2025-0007. in Gex, 2007, High Energy Ebeam Energy Calculation Using GEX Wedge Array Cards Risø Aluminum Wedge (4.5 to 12 MeV). https://library.gexcorp.com/wp-content/uploads/2025/07/100-204_A-Ebeam Energy-Determination-Using-GEX-Wedge-Array-Cards.pdf Hallman, G.J., 2006, Guidelines for The Use Of Irradiation as A Phytosanitary Treatment, ISPM No. 18, Jan, 2016. IAEA, 2002, Dosimetry for Food Irradiation, Technical Reports Series No. 409. IAEA, 2010, Use of Mathematical Modelling in Electron Beam Processing: A Guidebook, Technical Reports Series No. 1. Indarwatmi, M., Kuswadi, A.N., 2021, Uji in Vitro Dosis Iradiasi Gamma untuk 66 Perlakuan Fitosanitari Terhadap Hama Lalat Buah Bactrocera Carambolae (Diptera: Tephritidae), Prosiding Simposium Dan Pameran Teknologi Aplikasi Isotop Dan Radiasi, jakarta, Indonesia. IPPC, 2025, The Importance of Plant Health Within One Health, Commission On Phytosanitary Measures Nineteenth Session, Roma. ISO/ASTM, 2015, Standard Practice for Dosimetry in an Electron Facility for Radiation Processing at Energies between 300 keV and 25 MeV, No. 51649. JAEA, 2025, User’s Manual: Particle and Heavy Ion Transport code System (PHITS) — English version, Japan Atomic Energy Agency (JAEA), Japan. Jayaraman, S., Lanzl, L.H., 2004, Collision and Radiation Loss in Charged-Particle Interactions, Clinical Radiotherapy Physics, Berlin. Kim, J., Moreira, R.G., Castell-Perez, M.E., 2015, Improving Phytosanitary Irradiation Treatment of Mangoes Using Monte Carlo Simulation, Journal of Food Engineering, Vol. DOI:10.1016/j.jfoodeng.2014.10.005. 149, Ly, N.T., Chung, C. Van, Khanh, C.N., Hong, P.T.T., Binh, D., Thanh, L.Q., Tuan, V.A., Ngoc, N.D., Vy, N.T., Hien, P.T.T., Quynh, T.N.T., Hao, T.H.N., 2021, Effects of Electron Beam Irradiation On Dose Uniformity Ratio and Quality Of Hoa Loc Mango, Vietnam Conference on Nuclear Science and Technology, Vietnam. Pp. 137–143, Montgomary, D.C., Runger, G.J., 2011, Applied Statistics and Probability for engineers, John Wiley & Sons, United States of America. Nikandrovs, M., 2024, Monte Carlo Modelling of Kilovoltage Radiotherapy, Doctoral Thesis , University College Dublin. Noerachman, T., Cristin, A., Rahayu, R., Fitriati, Y., 2012, Pedoman Teknis Perlakuan Karantina Tumbuhan dengan Iradiasi Sinar Gamma, Seri Perlakuan Karantina Tumbuhan. Oh, S.-Y., Kim, J., Kwon, S.-H., Chung, S.-W., Kwon, S.-G., Park, J.-M., Choi, W.-S., 2014, Monte Carlo Simulation of Phytosanitary Irradiation Treatment for Mangosteen Using MRI-based Geometry, Journal of Biosystems Engineering, Vol. 39 (3), Hal. 205–214, DOI:10.5307/JBE.2014.39.3.205. Oliveira, P.S. de, Coelho, C.C. de S., Campos, R. da S., Freitas-Silva, O., Júnior, M.F., 2025, Effects of Electron-Beam (E-Beam) Irradiation on The Postharvest Quality of ‘Golden’ Papayas, Food Physics, Vol. 2, DOI:10.1016/j.foodp.2025.100054. Pierard, A., 2025, Expanding the Boundaries of IrradiationTransforming Industries with E-beam and X-ray, Hits the Road Southeast Asia Edition, Indonesia. Podgorsak, B.E, 2003, Radiation Oncology Physics: A Handbook for Teachers and Students, Edition 19th, IAEA, Vienna, Austria. 67 Podgorsak, E.B., 2016, Interactions of Charged Particles with Matter, Radiation Physics for Medical Physicists, Springer International Publishing Switzerland, Pp. 229–276. Sato, T., Iwamoto, Y., Hashimoto, S., Ogawa, T., Furuta, T., Abe, S., Kai, T., Matsuya, Y., Matsuda, N., Hirata, Y., Sekikawa, T., Yao, L., P.E.Tsai, Hunter, H.N., Iwase, H., Sakaki, Y., Sugihara, K., Shigyo, N., Sihver, L., Niita, K., 2024, PHITS’s Manual User Version 3.35, JAEA, Japan. Security, H.L., 2021, Compendium of Material Composition Data for Radiation Transport Modeling, Pacifict Nortwest National Laboratory, United States. Sinambela., B.R., 2024, Dampak Penggunaan Pestisida dalam Kegiatan Pertanian terhadap Lingkungan Hidup dan Kesehatan, Agrotek: Jurnal Ilmiah Ilmu Pertanian, Vol. 8 (2), DOI: 10.33096/agrotek.v8i2.625. Studenikin, F.R., Bliznyuk, U.A., Chernyaev, A.P., Khankin, V. V., Krusanov, G.A., 2021, Impact of Aluminum Plates on Uniformity of Depth Dose Distribution in Object during Electron Processing, Moscow University Physics Bulletin, Vol. 76, Pp. S1–S7, DOI:10.3103/S0027134922010106. Thao, P.T.T., Tuan, H.S.M., 2024, Impact of Electron Radiation on Bactrocera dorsalis Hendel Development on Dragon Fruit, IOP Conference Series: Earth and Environmental 1315/1399/1/012008. Radiation Physics in Science, Vol. 1399, DOI:10.1088/1755 Tong, J., Rakovski, C., Prakash, A., 2015, Phytosanitary Irradiation Preserves the Quality of Fresh Blueberries and Grapes during Storage, Hort Science, Vol. 50 (11), Pp. 1666–1670. DOI: 10.21273/HORTSCI.50.11.1666 Tuan, N.A., Tao, C. Van, Rangacharyulu, C., 2019, The Depth-Dose Curve Depends on The Inhomogeneity of The Material Irradiated by Electron Beam, and Chemistry, DOI:10.1016/j.radphyschem.2019.05.001. Vol. 163, Pp. 22–25, Vargasab, A., Brisona, J., 2023, X-Ray and E-Beam Irradiation for Phytosanitary Control Navel Oranges DOI:10.2139/ssrn.4540863. and Blueberries, PlumX Metrics, Walpole, R.E., Myers, R.H., Myers, S.L., Ye, K., 1993, Probability and Statistics for Engineers and Scientists, Edition 5th, Macmillan, New York. Wangler, T.P., 2008, RF Linear accelerators, John Wiley & Sons, United State America. Zolotov, S.A., Bliznyuk, U.A., Studenikin, F.R., Borshchegovskaya, P.Y., Krusanov, G.A., 2023, Combination of Aluminum Plates of Different Thicknesses to Increase the Homogeneity of Radiation Treatment by Accelerated Electrons, Physics of Particles and Nuclei Letters, Vol. 20, Pp. 954–958, DOI:10.1134/S1547477123040726. 68
local.eprints.dirdisk0/00/52/26/49
local.eprints.division03A
local.eprints.id522649
local.eprints.typethesis/2Sarjana
local.eprints.urihttp://scholar.unand.ac.id/522649/
local.fakultasFakultas Matematika dan Ilmu Pengetahuan Alam
local.identifier.nim2110441018
local.prodiS1 Fisika
local.thesis.levelSkripsi