UPT Perpustakaan Universitas Andalas
Repositori PerpustakaanUniversitas Andalas
 

Uji Stabilitas Biomekanik Fraktur Ramus Pubis Anterior pada Tikus Wistar (Rattus novergicus)

dc.contributor.authorMumtas, Humairoh Azizah
dc.date.accessioned2026-09-24T17:56:54Z
dc.date.issued2026-07-22
dc.descriptiondr. Noverial, Sp.OT : Dr. Dessy Arisanty, S.si, M. Sc
dc.description.abstractFraktur ramus pubis anterior merupakan bagian dari fraktur cincin pelvis yang umumnya tergolong stabil dan ditatalaksana secara konservatif. Meskipun demikian, stabilitas biomekanik fragmen tulang selama proses penyembuhan masih perlu dievaluasi untuk memahami respons mekanik terhadap pembebanan. Parameter biomekanik seperti interfragmentary movement, stiffness, dan strain digunakan untuk menilai respons tulang terhadap pembebanan. Penelitian ini bertujuan menganalisis stabilitas fraktur ramus pubis anterior pada tikus Wistar (Rattus norvegicus) berdasarkan nilai delta interfragmentary movement, stiffness, dan strain menggunakan force gauge serta analisis citra digital dengan perangkat lunak ImageJ. Penelitian ini menggunakan desain eksperimental ex vivo dengan pendekatan biomekanik pada 24 spesimen tulang pubis tikus Wistar dengan model fraktur ramus pubis anterior. Pembebanan dilakukan pada arah horizontal dan vertikal menggunakan force gauge, sedangkan interfragmentary movement dianalisis dengan ImageJ. Nilai stiffness dan strain dihitung berdasarkan respons biomekanik terhadap pembebanan. Data delta interfragmentary movement, stiffness, dan strain dianalisis menggunakan uji independent t-test. Hasil penelitian menunjukkan adanya perbedaan nilai pre-interfragmentary movement dan post-interfragmentary movement setelah penerapan protokol biomekanika pada pembebanan horizontal maupun vertikal. Nilai stiffness berhasil diukur pada kedua arah pembebanan. Distribusi nilai strain didominasi kategori 2–10% sebanyak 23 dari 24 spesimen (95,83%), sedangkan 1 spesimen (4,17%) berada pada kategori <2%. Analisis statistik menunjukkan bahwa arah pembebanan horizontal dan vertikal tidak memberikan pengaruh yang bermakna terhadap nilai delta interfragmentary movement, stiffness, maupun strain (p>0,05). Kesimpulannya, stabilitas fraktur ramus pubis anterior pada tikus Wistar menunjukkan respons biomekanik yang serupa antara pembebanan horizontal dan vertikal berdasarkan parameter interfragmentary movement, stiffness, dan strain, dengan distribusi strain yang didominasi kategori 2–10%.
dc.identifier.urihttps://ailib.my.id/handle/123456789/8716
dc.language.isoid
dc.publisherUniversitas Andalas
dc.subjectfraktur ramus pubis anterior
dc.subjectInterfragmentary movement
dc.subjectstiffness
dc.subjectstrain
dc.subject.classificationR Medicine (General)
dc.subject.classificationRD Surgery
dc.titleUji Stabilitas Biomekanik Fraktur Ramus Pubis Anterior pada Tikus Wistar (Rattus novergicus)
dc.typeThesis
dcterms.dateSubmitted2026-08-08
dcterms.referencesRachman T, Rahmadian R, Rusjdi SR. Pola penatalaksanaan fraktur femur di RSUP Dr. M. Djamil Padang tahun 2020. J Ilmu Kesehat Indones. 2023;4(2):81–7. Aryana IGADP, Mergawa PF, Maharjana MA. Karakteristik pasien fraktur pelvis di unit gawat darurat RSUP Prof. Dr. I.G.N.G. Ngoerah periode Januari 2019–September 2022. Intisari Sains Medis. 2023;14(1):28–35. Kementerian Kesehatan Republik Indonesia. Riset Kesehatan Dasar (Riskesdas) 2018. Jakarta: Kementerian Kesehatan RI; 2018. Sastra L, Despitasari L. Pengaruh terapi dingin (cryotherapy) terhadap penurunan nyeri pada fraktur ekstremitas tertutup. J Kesehat Hesti Wira Sakti [Internet]. 2018;6(2):28–36. Available from: https://jurnal.poltekkes-soepraoen.ac.id/index.php/HWS/article/view/242. Nur As Salaam. Peranan proyeksi anteroposterior inlet dan outlet terhadap informasi anatomi pelvis pada kasus fraktur (studi literatur) [Internet]. Yogyakarta: Universitas ‘Aisyiyah Yogyakarta; 2021. Available from: http://digilib.unisayogya.ac.id/5998/1/NUR%20AS%20SALAAM_1810505084_NASKAH%20PUBLIKASI.pdf. Putra FM, Mappaware NA, Rijal S, Makmun A, Syamsu RF. Laporan kasus: analisis kasus fraktur dalam perspektif medis, bioetik dan Islam. 2024;8:3931–40. Chilmi MZ, Dilogo IH. Definitive management option of pelvic ring injury. Hip Knee J. 2021;2(2):57–67. Moore MC. Pelvic fracture management in the emergency department [Internet]. 2023 [cited 2024 Mar 2]. Available from: https://emedicine.medscape.com/article/825869. Efarina S, Berastagi E. Intervensi radiologis dalam menegakkan diagnosis fraktur ramus superior dan inferior Pelvis dextra. 2023;13:306–10. Brown MJC, O’Flaherty EJ, Jenkins PJ. Predicting patient-reported outcome in total knee arthroplasty using body mass index and limb measurements. Knee [Internet]. 2018; Available from: https://doi.org/10.1016/j.knee.2018.06.015. Burgio V, Casari S, Milizia M, Sanna F, Spezia G, Civera M, et al. Mechanical properties of animal ligaments: a review and comparative study. Biomech Model Mechanobiol [Internet]. 2023;22:1645–83. Available from: https://doi.org/10.1007/s10237-023-01718-1. Rommens PM, Dietz S, Ossendorf C, Pairon P, Wagner D, Hofmann A. Fragility fractures of the pelvis: should they be fixed? Acta Chir Orthop Traumatol Cech [Internet]. 2015;82(2):101–12. Abbas M, Mus R, Fitriana T. Perbandingan kadar kalsium pada wanita premenopause dan menopause sebagai faktor risiko osteoporosis. 2023;3:3316–25. Apley AG, Solomon L. Apley and Solomon’s system of orthopaedics and trauma. Blom A, Warwick D, Whitehouse M, editors. 10th ed. London: CRC Press; 2018. Rommens PM, Hopf JC, Herteleer M, Devlieger B, Hofmann A, Wagner D. Isolated pubic ramus fractures in elderly persons: an observational study. 2020;9(8). Fensky F, Weiser L, Sellenschloh K, Vollmer M, Hartel MJ, Morlock MM, et al. Biomechanical analysis of anterior pelvic ring fractures. Eur J Trauma Emerg Surg. 2021;47(1):187–93. Sibarani E. Fleksibilitas pada wilayah lumbal [Internet]. 2019. Available from: https://repository.uhn.ac.id. Wirman RP, Kartika R, Wirman SP. Rancang bangun alat ukur modulus elastisitas material menggunakan sensor force gauge. 2023;8. Gidion H, Sugianto JP, Betty P. Penerapan kerangka acuan biomekanik pada kasus fraktur distal radius ulna. J Fisioter Terapan Indones. 2023;2(1). Prastyo Wati D. Prinsip dasar tikus sebagai model penelitian. USU Press. 2024;1(1):6–10. Maynard RL, Downes N. Anatomy of the laboratory rat. London: Academic Press; 2019. p. 23–39. Ks SR, Sridevi P, Asmitha S, Ramesh G. Anatomy of the hind limb bones of Wistar rat. 2023;12(9):2668–71. Grassi L, Isaksson H. Extracting accurate strain measurements in bone mechanics: A critical review of current methods. J Mech Behav Biomed Mater. 2015;50:233–247. doi:10.1016/j.jmbbm.2015.06.006. Hosoido T, Mori F, Kiyoto K, Takagi T, Sano Y, Goto M, Nakajima K, Wada N. Qualitative comparison between rats and humans in quadrupedal and bipedal locomotion. J Behav Brain Sci. 2013;3(1):137-49. doi:10.4236/jbbs.2013.31013. Lei J, Zhang Y, Wu G, Wang Z, Chen X. The influence of pelvic ramus fracture on stability of pelvic complex fracture. Comput Math Methods Med. 2015; Heaney F, Santy-Tomlinson J. Principles of trauma care. Orthop Trauma Nurs. 2014. p. 199–220. Russell GV. Pelvic fractures [Internet]. 2024 [cited 2024 Apr 30]. Available from: https://emedicine.medscape.com. Kiapour A, Joukar A, Elgafy H, Erbulut DU, Agarwal AK, Goel VK. Biomechanics of the sacroiliac joint. 2020;14(Suppl 1):S3–13. Drake RL, Vogl AW, Mitchell AWM. Gray’s basic anatomy. Philadelphia: Elsevier; 2014. Ricci PL, Maas S, Kelm J, Gerich T. Finite element analysis of the pelvis including gait muscle forces: an investigation into the effect of rami fractures on load transmission. J Exp Orthop. 2018;5(1):33. Zhang S, Ueno D, Ohira T, Kato H, Izawa T, Yamanouchi S, et al. Depression of bone density in Wistar rats. Front Physiol. 2021;9:707470. Younus A, Ncobela N, et al. Orthopaedic management of pelvic fractures: a literature review. 2020;14(2):88–94. Petrescu FIT, Apicella A, Petrescu RV, Calautit JK, Riccio A. Mechanical moment of inertia. Am J Appl Sci. 2016;13(11):1085–90. Coccolini F, Stahel PF, Montori G, et al. Pelvic trauma: WSES classification and guidelines. World J Emerg Surg. 2017;12:5. Harvey H, Hacking C, Tan W, et al. Pelvic fractures. Radiopaedia.org. 2011. Miller JD, Cabarkapa D, Miller AJ, Frazer LL, Templin TN, Eliason TD, et al. Novel 3D force sensors. Sensors. 2023;23(9). Ceynowa M, Zerdzicki K, Klosowski P, Pankowski R, Rocławski M, Mazurek T. Early failure of gamma nail and DHS. Clin Biomech. 2020;71:201–7. Mallick DD, Zhao M, Bosworth BT, Schuster BE, Foster MA, Ramesh KT. Photon Doppler velocimeter. Exp Mech. 2019;59(1):41–9. Arıtan S. Biomechanical measurement methods to analyze the mechanisms of sport injuries. Sport Inj. 2014;1–13. Daniels AH, Paller DJ, Koruprolu S, Palumbo MA, Crisco JJ. Dynamic Biomechanical Examination of the Lumbar Spine with Implanted Total Spinal Segment Replacement (TSSR) Utilizing a Pendulum Testing System. PLoS One. 2013;8(2). Çavusoglu AT, Erbay FK, Özsoy MH, Demir T. Biomechanical comparison of supraacetabular external fixation and anterior pelvic bridge plating. Proc Inst Mech Eng Part H J Eng Med. 2017;231(10):931–7. Lodde MF, Katthagen JC, Schopper CO, Zderic I, Richards G, Gueorguiev B, et al. Biomechanical comparison of five fixation techniques for unstable fragility fractures of the Pelvic ring. J Clin Med. 2021;10(11). Grassi L, Isaksson H. Extracting accurate strain measurements in bone mechanics: A critical review of current methods. J Mech Behav Biomed Mater. 2015;50:233–47. doi:10.1016/j.jmbbm.2015.06.006. Cheal EJ, Mansmann KA, DiGioia AM III, Hayes WC, Perren SM. Role of interfragmentary strain in fracture healing: Ovine model of a healing osteotomy. J Orthop Res. 1991;9(1):131–42. Kawasaki Y, Ogawa A, Takahashi H. Force plate with simple mechanical springs and separated noncontact sensor elements. Sensors (Basel). 2021;21(21):1–15. Bocchetta G, Fiori G, Sciuto SA, Scorza A. Performance of smart materials-based instrumentation for force measurements in biomedical applications: A methodological review. Actuators. 2023;12(7):267. Grosse IR, Mitchell LD. Nonlinear axial stiffness characteristics of axisymmetric bolted joints. J Mech Des. 1990;112(3):442–9. Berk T, Zderic I, Varga P, Schwarzenberg P, Berk K, Grüneweller N, Pastor T, Halvachizadeh S, Richards G, Gueorguiev B, Pape HC. Substitutional semi-rigid osteosynthesis technique for treatment of unstable pubic symphysis injuries: a biomechanical study. Eur J Trauma Emerg Surg. 2023;49:2569–78. Foster AL, Moriarty TF, Zalavras C, Morgenstern M, Jaiprakash A, Crawford R, et al. The influence of biomechanical stability on bone healing and fracture-related infection: the legacy of Stephan Perren. Injury. 2021;52(Suppl 1):S43–52. Schell H, Epari DR, Kassi JP, Bragulla H, Bail HJ, Duda GN. The course of bone healing is influenced by the initial shear fixation stability. J Orthop Res. 2005;23(5):1022–8. Claes LE, Heigele CA. Magnitudes of local stress and strain along bony surfaces predict the course and type of fracture healing. J Biomech. 1999;32(3):255–66. Zimmer L, Britz R, Goergen Y, Rizzello G, Pohlemann T, Orth M, et al. An SMA-based multifunctional implant for improved bone fracture healing. Materials (Basel). 2021;14:1–14. 53. Ossendorf C, Wagner D, Hofmann A. Fragility fractures of the sacrum: how to identify and when to treat surgically? Eur J Trauma Emerg Surg. 2025;51:349–62. Peez C, Milstrey A, Zderic I, Deichsel A, Raschke MJ, Herbst E. The type of lateral hinge fracture in medial open-wedge high tibial osteotomy determines its stability: a biomechanical study. Knee Surg Sports Traumatol Arthrosc. 2025;33:1622–8. Sengupta R, Dhason R, Merdji A, Roy S, Basu P. Biomechanical analysis of composite bone plates for tibial oblique fracture repair using finite element analysis. 2026. Steiner M, Claes L, Ignatius A, Niemeyer F, Simon U, Wehner T, et al. Prediction of fracture healing under axial loading, shear loading and bending is possible using distortional and dilatational strains as determining mechanical stimuli. J R Soc Interface. 2013. Osagie-clouard L, Kaufmann J, Blunn G, Coathup M, Pendegrass C, Meeson R, et al. Biomechanics of two external fixator devices used in rat femoral fractures. 2018;37(2):1–23. Haffner-Luntzer M, Ignatius A. Animal models for studying metaphyseal bone fracture healing. Eur Cell Mater. 2020;40:172–88. Sheen JR, Mabrouk A, Garla VV. Fracture healing overview. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026. Available from: https://www.ncbi.nlm.nih.gov/books/NBK551678/ . 60. Baker CE, Moore-Lotridge SN, Hysong AA, Posey SL, Robinette JP, Blum DM, et al. Bone fracture acute phase response: a unifying theory of fracture repair: clinical and scientific implications. Clin Rev Bone Miner Metab. 2018;16:142–58. Wier J, Shelby H, Bergren S, Patterson JT, Lieberman JR. Modern approaches and emerging biological therapies to treat fracture nonunion. J Bone Miner Res. 2025;1–41. Prodinger PM, Bürklein D, Foehr P, Kreutzer K, Pilge H, Schmitt A, et al. Improving results in rat fracture models: enhancing the efficacy of biomechanical testing by a modification of the experimental setup. BMC Musculoskelet Disord. 2018;19:1–8. Sommer NG, Hahn D, Okutan B. Animal models in orthopedic research: the proper animal model to answer fundamental questions on bone healing depending on pathology and implant material. J Funct Biomater. 2019
local.eprints.dirdisk0/00/52/80/97
local.eprints.divisionS1KEDOK2024
local.eprints.id528097
local.eprints.typethesis/2Sarjana
local.eprints.urihttp://scholar.unand.ac.id/528097/
local.fakultasFakultas Kedokteran
local.identifier.nim2110312058
local.prodiS1 Kedokteran
local.thesis.levelSkripsi

Files

Collections