Parametric Study of Shear Wall Configuration on Seismic Performance of a 5-Story RC Building in Padang Using Pushover Analysis

dc.contributor.authorTeja, Asher Besthianli
dc.date.accessioned2026-09-24T21:30:00Z
dc.date.issued2026-01-29
dc.descriptionIr Masrilayanti, S.T, M.Sc., PhD
dc.description.abstractIndonesia, situated within the Pacific Ring of Fire, faces significant seismic risks, particularly in coastal cities like Padang. Many existing mid-rise Reinforced Concrete (RC) buildings in this region were designed using older codes and may lack adequate lateral stiffness, rendering them vulnerable to structural failure during major earthquakes. While adding shear walls is a proven retrofitting strategy to enhance structural resilience, the effectiveness of this method is highly sensitive to the wall placement relative to the building’s inherent geometric irregularities. Therefore, determining the optimal configuration is crucial to ensure both safety and cost-effectiveness. This study utilizes Nonlinear Static (Pushover) Analysis in SeismoStruct to evaluate the seismic performance of a 5-story RC building. A preliminary modal analysis identified a critical stiffness deficiency in the transverse (X) direction (Tx > Ty), which guided the design of three retrofit schemes: Exterior (Model 2), Interior (Model 3), and Hybrid (Model 4) placements. The parametric analysis reveals that the existing structure (Model 1) is vulnerable to torsional instability and fails to meet the Life Safety (LS) performance level. The results confirm that while all schemes improved global stiffness, Model 2 (Exterior Alignment) emerged as the most effective strategy. It successfully mitigated the collapse risk, satisfied LS criteria in both orthogonal directions, and significantly reduced the torsion effect of the building. In conclusion, specifically for building geometries characterized by a dominant weak axis in the transverse direction, placing shear walls at the exterior perimeter is proven to be the superior solution. This configuration effectively balances the center of rigidity, minimizes torsional effects, and prevents the premature brittle shear failure observed in the interior and hybrid configurations.
dc.identifier.urihttps://ailib.my.id/handle/123456789/51093
dc.language.isoid
dc.publisherUniversitas Andalas
dc.subjectShear Wall Configuration
dc.subjectSeismoStruct
dc.subjectPushover Analysis
dc.subjectSeismic Performance
dc.subjectReinforced Concrete Building
dc.subjectPadang
dc.subject.classificationTA Engineering (General). Civil engineering (General)
dc.titleParametric Study of Shear Wall Configuration on Seismic Performance of a 5-Story RC Building in Padang Using Pushover Analysis
dc.typeThesis
dcterms.dateSubmitted2026-01-29
dcterms.referencesAji, H. S., Rosyidah, A., & Saputra, J. (2022). The effect of variation of shear walls placement on the response of building structure using the direct displacement-based design method. SINERGI, 26(2), 201–212. https://doi.org/10.22441/sinergi.2022.2.009 American Society of Civil Engineers. (2023). Seismic evaluation and retrofit of existing buildings (ASCE/SEI 41-23). American Society of Civil Engineers. Anwar, N. (2015). Performance-based design: An approach towards safer, reliable structures. Technology, 58. https://www.researchgate.net/publication/275346726 Badan Standardisasi Nasional. (2019). Persyaratan beton struktural untuk bangunan gedung (SNI 2847:2019). Badan Standardisasi Nasional. www.bsn.go.id Badan Standardisasi Nasional. (2020). Beban desain minimum dan kriteria terkait untuk bangunan gedung dan struktur lain (SNI 1727:2020). Badan Standardisasi Nasional. Daswita, A., Pujiastuti, D., & Anggono, T. (2023). Studi bahaya seismik dengan metode probabilistic seismic hazard analysis di Sumatera Barat. Jurnal Fisika Unand, 12(3), 445–451. https://doi.org/10.25077/JFU.12.3.444-450.2023 Gwalani, P., & Singh, Y. (2023). Performance-based seismic design of RC structures. In Recent advances in earthquake engineering (pp. 309–330). Springer. https://doi.org/10.1007/978-981-19-2324-1_13 Hakim, R. A., Alama, M. S., & Ashour, S. A. (2014). Seismic assessment of RC building according to ATC 40, FEMA 356 and FEMA 440. Arabian Journal for Science and Engineering, 39(11), 7691–7699. https://doi.org/10.1007/S13369-014-1395-X Hasan, R., Xu, L., & Grierson, D. E. (2002). Push-over analysis for performance-based seismic design. Computers & Structures, 80(31), 2483–2493. https://doi.org/10.1016/S0045-7949(02)00212-2 Kementerian Pekerjaan Umum dan Perumahan Rakyat. (2021). Desain spektra Indonesia. https://rsa.ciptakarya.pu.go.id/2021 Khelaifia, A., Chebili, R., & Zine, A. (2024). Impact of the position and quantity of shear walls in buildings on the seismic performance. Asian Journal of Civil Engineering, 25(1), 953–964. https://doi.org/10.1007/s42107-023-00824-w Marab, B., & Marsono, A. K. (2016). A numerical and analytical study on optimization and efficiency of structural forms by two-outrigger in tall buildings. Malaysian Journal of Civil Engineering, 28(3), 163–179. https://www.researchgate.net/publication/314841019 Masrilayanti, Hasibuan, Y. A., Kurniawan, R., Sunaryati, J., & Fitrah, R. A. (2023). Performance evaluation of high-rise apartment building using pushover analysis. E3S Web of Conferences, 429, 05024. https://doi.org/10.1051/e3sconf/202342905024 Mouhine, M., Derife, M., Aboumdian, S., & Hilali, E. (2024). Improving seismic vulnerability of irregular reinforced concrete moment-resisting frames using shear walls. International Journal of Engineering, Transactions B: Applications, 37(2), 425–438. https://doi.org/10.5829/ije.2024.37.02b.17 Ozkul, T. A., Kurtbeyoglu, A., Borekci, M., Zengin, B., & Kocak, A. (2019). Effect of shear wall on seismic performance of RC frame buildings. Engineering Failure Analysis, 100, 60–75. https://doi.org/10.1016/j.engfailanal.2019.02.032 Putra, R. R., Parajuli, H. R., Kiyono, J., & Ono, Y. (2012). Seismic hazard analysis for Indonesia. Journal of Natural Disaster Science, 33(2), 59–70. SeismoSoft. (2021). SeismoStruct 2021 – A computer program for static and dynamic nonlinear analysis of framed structures. SeismoSoft. https://seismosoft.com Sieh, K., & Natawidjaja, D. (2000). Neotectonics of the Sumatran fault, Indonesia. Journal of Geophysical Research: Solid Earth, 105(B12), 28295–28326. https://doi.org/10.1029/2000jb900120 Tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung (SNI 1726:2019). (2019). Badan Standardisasi Nasional. www.bsn.go.id
local.eprints.dirdisk0/00/51/97/59
local.eprints.division07C
local.eprints.id519759
local.eprints.typethesis/2Sarjana
local.eprints.urihttp://scholar.unand.ac.id/519759/
local.fakultasFakultas Teknik
local.identifier.nim2210922029
local.prodiS1 Teknik Sipil
local.thesis.levelSkripsi