PENERAPAN METODE WAVELET MULTIRESOLUTION ANALYSIS UNTUK MENGIDENTIFIKASI JENIS GANGGUAN PADA SALURAN TRANSMISI 150 kV
| dc.contributor.advisor | Novizon, Novizon | |
| dc.contributor.author | Muhammad, Haykal Ramadhan | |
| dc.date.accessioned | 2026-09-24T21:24:18Z | |
| dc.date.issued | 2024-11-12 | |
| dc.description | Ir Novizon, M.Eng. Ph.D | |
| dc.description.abstract | The application of the Wavelet Multiresolution Analysis (MRA) method in this study aims to identify various types of faults occurring in a 150 kV transmission line with high speed and accuracy, addressing complex protection challenges in electrical transmission networks. MRA ability to decompose signals across multiple frequency scales and resolutions facilitates the effective identification of diverse fault types. Simulations were conducted using ATP and Matlab software, modeling the transmission system between the Maninjau Hydroelectric Power Plant (PLTA) and the Pauh Limo Substation (GI), subjected to fault types such as single-phase-to-ground, double-phase-to-ground, double-phase, three-phase, and lightning faults. To enhance the accuracy of fault identification, variations in fault distance and impedance were applied in the simulations. Based on an analysis of simulation results that includes calculating average approximation coefficients from the MRA method, it was concluded that this method can effectively identify and classify all fault types studied, meeting the accuracy criteria established for transmission system protection. | |
| dc.identifier.uri | https://ailib.my.id/handle/123456789/50089 | |
| dc.language.iso | id | |
| dc.publisher | Universitas Andalas | |
| dc.subject | Transmission Lines | |
| dc.subject | Wavelet Multiresolution | |
| dc.subject.classification | TK Electrical engineering. Electronics Nuclear engineering | |
| dc.title | PENERAPAN METODE WAVELET MULTIRESOLUTION ANALYSIS UNTUK MENGIDENTIFIKASI JENIS GANGGUAN PADA SALURAN TRANSMISI 150 kV | |
| dc.type | Thesis | |
| dcterms.dateSubmitted | 2025-01-21 | |
| dcterms.references | [1] T. W. Ross and H. G. Bell, “Recent developments in the protection of three-phase transmission lines and feeders,” J. Inst. Electr. Eng., vol. 68, no. 403, pp. 801–823, 1930, doi: 10.1049/jiee-1.1930.0090. [2] A. R. Adly, S. H. E. Abdel Aleem, M. A. Elsadd, and Z. M. Ali, Wavelet packet transform applied to a series-compensated line: A novel scheme for fault identification, vol. 151. Elsevier Ltd, 2020. doi: 10.1016/j.measurement.2019.107156. [3] S. A. Probert and Y. H. Song, “Detection and classification of high frequency transients using wavelet analysis,” Proc. IEEE Power Eng. Soc. Transm. Distrib. Conf., vol. 2, no. SUMMER, pp. 801–806, 2002, doi: 10.1109/pess.2002.1043437. [4] O. A. S. Youssef, “Combined fuzzy-logic wavelet-based fault classification technique for power system relaying,” IEEE Trans. Power Deliv., vol. 19, no. 2, pp. 582–589, 2004, doi: 10.1109/TPWRD.2004.826386. [5] S. T. Lines, A. I. Megahed, A. M. Moussa, and A. E. Bayoumy, “Usage of Wavelet Transform in the Protection of,” vol. 21, no. 3, pp. 1213–1221, 2006. [6] F. E. Pérez, E. Orduña, and G. Guidi, “Adaptive wavelets applied to fault classification on transmission lines,” IET Gener. Transm. Distrib., vol. 5, no. 7, pp. 694–702, 2011, doi: 10.1049/iet-gtd.2010.0615. [7] R. Mahanty and P. Gupta, “Application of RBF neural network to fault classification and location in transmission line,” IEE Proceedings-Generation, Transm. …, vol. 151, no. 3, pp. 201–212, 2004, doi: 10.1049/ip-gtd. [8] S. Seyedtabaii, “Improvement in the performance of neural network-based power transmission line fault classifiers,” IET Gener. Transm. Distrib., vol. 6, no. 8, pp. 731–737, 2012, doi: 10.1049/iet-gtd.2011.0757. [9] Z. He, S. Lin, Y. Deng, X. Li, and Q. Qian, “A rough membership neural network approach for fault classification in transmission lines,” Int. J. Electr. Power Energy Syst., vol. 61, pp. 429–439, 2014, doi: 10.1016/j.ijepes.2014.03.027. [10] O. A. S. Youssef, “A novel fuzzy-logic-based phase selection technique for power system relaying,” Electr. Power Syst. Res., vol. 68, no. 3, pp. 175–184, 2004, doi: 10.1016/j.epsr.2003.06.006. [11] K. M. Silva, B. A. Souza, and N. S. D. Brito, “Fault detection and classification in transmission lines based on wavelet transform and ANN,” IEEE Trans. Power Deliv., vol. 21, no. 4, pp. 2058–2063, 2006, doi: 10.1109/TPWRD.2006.876659. [12] H. Wang, And, and W. W. L. Keerthipala, “Fuzzy-neuro approach to fault classification for transmission line protection,” vol. 13, no. 4, pp. 1093–1104, 1998. [13] S. Vasilic and M. Kezunovic, “Fuzzy ART neural network algorithm for classifying the power system faults,” IEEE Trans. Power Deliv., vol. 20, no. 2 II, pp. 1306–1314, 2005, doi: 10.1109/TPWRD.2004.834676. [14] A. Nag and A. Yadav, “Fault classification using Artificial Neural Network in combined underground cable and overhead line,” 1st IEEE Int. Conf. Power Electron. Intell. Control Energy Syst. ICPEICES 2016, pp. 1–4, 2017, doi: 10.1109/ICPEICES.2016.7853664. [15] M. Amir and I. A. Winarno, “Analisis Susut Tegangan Saluran Transmisi Tegangan Ekstra Tinggi 500 kV,” Sinusoida, vol. XXII, no. 2, pp. 1–9, 2020, [Online]. Available: https://ejournal.istn.ac.id/index.php/sinusoida/article/view/692%0Ahttps://ejournal.istn.ac.id/index.php/sinusoida/article/download/692/502. [16] A. Nurdin and A. Azis, “Pengaruh Jarak Antar Sub Konduktor Berkas Reaktansi Induktif Saluran Terhadap Transmisi 150 Kv Dari Gardu Induk Keramasan Ke Gardu Induk Mariana,” J. Ampere, vol. 3, no. 2, p. 145, 2018, doi: 10.31851/ampere.v3i2.2395. [17] W. Zhang et al., “SLG ( Single-Line-to-Ground ) Fault Location in NUGS ( Neutral Un-effectively Grounded System ) 2 The Characteristics of SLG Fault and 3 Review of SLG Fault Location Methods,” vol. 01009, pp. 1–6, 2018. [18] M. Izadi, M. S. Abd Rahman, M. Z. A. Ab-Kadir, C. Gomes, J. Jasni, and M. Hajikhani, “The influence of lightning induced voltage on the distribution power line polymer insulators,” PLoS One, vol. 12, no. 2, pp. 1–22, 2017, doi: 10.1371/journal.pone.0172118. [19] W. Fluty and Y. Liao, “Electric Transmission Fault Location Techniques Using Traveling Wave Method and Discrete Wavelet Transform,” Clemson Univ. Power Syst. Conf. PSC 2020, 2020, doi: 10.1109/PSC50246.2020.9131271. [20] P. Chiradeja and C. Pothisarn, “Identification of the fault location for three-terminal transmission lines using discrete wavelet transforms,” Transm. Distrib. Conf. Expo. Asia Pacific, T D Asia 2009, pp. 3–6, 2009, doi: 10.1109/TD-ASIA.2009.5356924. [21] S. Hakim, M. I. . Zul, and M. Akbar, “Performance of Discrete Wavelet Transform on CCTV Images Data Decomposition,” Eng. Tech. Res. , vol. 8, no. 4, pp. 2454–4698, 2018, [Online]. Available: www.erpublication.org [22] I. Omerhodzic, S. Avdakovic, A. Nuhanovic, and K. Dizdarevic, “Energy distribution of EEG signals: EEG signal wavelet-neural network classifier,” World Acad. Sci. Eng. Technol., vol. 37, no. July, pp. 1240–1245, 2010. [23] M. Choudhury and A. Ganguly, “Transmission line fault classification using discrete wavelet transform,” 2015 Int. Conf. Energy, Power Environ. Towar. Sustain. Growth, vol. 151, pp. 10–17, 2015 | |
| local.eprints.dir | disk0/00/48/62/72 | |
| local.eprints.division | 07B | |
| local.eprints.id | 486272 | |
| local.eprints.type | thesis/2Sarjana | |
| local.eprints.uri | http://scholar.unand.ac.id/486272/ | |
| local.fakultas | Fakultas Teknik | |
| local.identifier.nim | 2010951041 | |
| local.prodi | S1 Teknik Elektro | |
| local.thesis.level | Skripsi |