dc.description.abstractIn the 21st century, high-rise building is one factor as a solution for residence and offices. Then, high-rise buildings can accommodate a lot of people in a limited area. The height of high-rise buildings is directly proportional to their vulnerability to fluctuation forces like earthquakes and wind. Tuned liquid column damper (TLCD) systems are passive mass dampers that don’t need external energy to suppress the vibration response. This type of damper can effectively decrease the structure response when the TLCD parameters such as natural frequency and damping ratio are selected. In the research, the natural frequency and damping ratio of TLCD are determined using the pendulum type of TLCD. Experimental testing with pendulum type of TLCD is varied with the number of orifices and the volume of water inside. There are 4 types of TLCD with 2 holes orifice, 4 holes orifice, 6 holes orifice, and 8 holes orifice. Each type of TLCD is varied with 200 ml, 300 ml, 400 ml, and 500 ml of water inside. After the natural frequency and damping ratio were obtained, the optimum parameter is chosen. The simulation study based on optimum pendulum type of TLCD parameter was conducted with a two-story structure model to see the performance of TLCD suppress vibration response. Then, to validate the result from the simulation, the experiment was conducted with the same parameter from the simulation. The result shows the natural frequency and damping ratio of TLCD can be determined using the pendulum type of TLCD. The TLCD with 4 holes and 400 ml of water has the best parameter to suppress vibration response. From experiment and simulation results, this type of TLCD can dampen vibration of structure up to 87.3% and 67.09%, respectively.
dc.identifier.urihttps://ailib.my.id/handle/123456789/48511
dc.language.isoid
dc.publisherUniversitas Andalas
dc.subjectTLCD
dc.subjectorifice
dc.subjectnatural frequency
dc.subjectdamping ratio
dc.subject.classificationTJ Mechanical engineering and machinery
dc.titleINVESTIGATION OF TUNED LIQUID COLUMN DAMPER FREQUENCY AND DAMPING RATIO WITH DIFFERENT NUMBERS OF ORIFICE
dc.typeThesis
dcterms.dateSubmitted2022-06-20
dcterms.references[1] Sarkar, A., Gudmestad, O., “Pendulum Type Liquid Column Damper (PLCD) For Controlling Vibrations Of a Structure – Theoretical and Experimental Study,” Engineering Structures, Vol. 49, pp. 221-233, 2013. [2] Son, L., Bur, M., Rusli, M., “Kaji Eksperimental Penerapan Peredam Dinamik TLCD dan TMD pada Model Struktur Geser Dua Derajat Kebebasan,” Seminar Nasional Tahunan Teknik Mesin XIV, 2015. [3] Gao, H., and Kwok, K.C.S, “Optimization of Tuned Liquid Column Dampers,” Engineering Structures, Vol. 19, pp. 476-486, 1997. [4] Govi, R.Y., “Kaji Eksperimental Untuk Kerja Peredam Dinamik Tuned Liquid Column Damper dan Sistem Massa Pegas dan Struktur Bangunan,” Tugas Akhir, Mechanical Engineering Departement, Andalas University, Padang, 2015. [5] Min, K.W., Kim, Y.W., Kim, J., “Analytical and experimental investigations on the performance of tuned liquid column dampers with various orifices to wind-excited structural vibration,” Journal of Wind Engineering and Industrial Aerodynamics, Vol. 139, pp. 62-69, 2015. [6] Reiterer, M. and Hochrainer, M., “Investigation of Parametric Resonance in Tuned Liquid Column Damper,” Application Mathematics and Mechanical, Vol. 3, pp. 122-123, 2003. [7] Reiterer, M. and Ziegler, F., “Combined Seismic Activation of an SDOF-Building with a passive TLCD attached,” 13th World Conference on Earthquake Engineering,” pp. 226, 2004. [8] Son, L., Bur, M., Rusli, M., “Response Reduction of Two-DOF Shear Structure Using TMD and TLCD by Considering Absorber Space Limit and Fluid Motion,” Applied Mechanics and Materials, Vol. 836, pp. 251-256, 2016. [9] Ballard, J., “The Simple Harmonic Pendulum,” 2012 [10] Wynn, J., “Motion of a Pendulum,” Undergraduate Journal of Mathematical Modelling: One + Two, Vol. 3, Issue 1, Article 9, 2010. [11] Bur, M. (2012). “Dasar-Dasar Getaran Mekanik.” Padang : CV. Ferila. [12] Ghorbani, H., D.A, Wood. (2008). “Prediction of oil flow rate through an orifice flow meter: Artificial Intelligence alternatives compared,” Petroleum. [13] Semmlow, J., “Linear Systems in the Frequency Domain: The Transfer Function,” 2018. [14] Hatch, M. (2001). “Vibration Simulation Using MATLAB and ANSYS.” [15] OMEGA Inc. (2006). “OMEGA Model IH101 Impulse Hammer: Operator’s Manual.” USA, MA: Author.