PENENTUAN TINGKAT AKURASI DOSIMETRI BERBASIS DATA TUNGGAL PADA TERAPI 177Lu-DOTATATE MENGGUNAKAN PENCITRAAN SPECT/CT DAN FITTING BAYESIAN
| dc.contributor.author | Rizka, Mutik Siyami | |
| dc.contributor.other | Sri, Oktamuliani | |
| dc.contributor.other | Deni, Hardiansyah | |
| dc.date.accessioned | 2026-09-24T23:40:42Z | |
| dc.date.issued | 2023-02-01 | |
| dc.description | Sri Oktamuliani, S.Si., M.Si., Ph.D Dr. sc. hum. Deni Hardiansyah, S.Pd., M.Si | |
| dc.description.abstract | Metode Bayesian mampu memperhitungkan nilai ketidakpastian individual dosis serap dari hasil perhitungan Time Integreted Activity Coefficient (TIAC) berdasarkan data pengukuran Single Time Point Dosimetry (STPD). Penelitian ini bertujuan untuk mengetahui tingkat akurasi dari model STPD, Two Time Point Dosimetry (2TPD), dan Three Time Point Dosimetry (3TPD) terhadap model All Time Point Dosimetry (ATPD), serta untuk mengetahui ketidakpastian TIAC dari semua model yang di-fitting menggunakan metode Bayesian. Penelitian ini penting dilakukan guna mengetahui tingkat akurasi dosis serap yang diberikan kepada pasien. Metode bayesian dipilih karena metode tersebut dapat memberikan nilai ketidakpastian pada satu data pengukuran. Data aktivitas digunakan pada waktu tertentu dari organ ginjal 8 pasien yang diinjeksi 177Lu-DOTATATE dengan pencitraan SPECT/CT. Data tersebut dikumpulkan dari publikasi Devasia pada tahun 2021. Pengelompokan data menjadi 5 grup waktu (G1-G5) lalu di-fitting menggunakan fungsi monoeksponensial dengan metode Bayesian. Selanjutnya dilakukan perhitungan nilai TIAC untuk semua titik data yang kemudian disebut TIAC ATPD dan nilai TIAC dari satu titik data serta kombinasi dua maupun tiga titik data yang selanjutnya disebut TIAC STPD, 2TPD, dan 3TPD. Didapatkan nilai persentase kesalahan terhadap model ATPD secara populasi untuk model STPD sebesar 1,8±9,58%; model 2TPD G3-1 sebesar -0,6±6,22%; model 3TPD G3-1-5 sebesar -0,03±7,70%; dan model Hänscheid sebesar -2,4±19,26%. Tingkat akurasi nilai TIAC STPD, 2TPD, dan 3TPD hasil pengolahan menggunakan metode Bayesian berdasarkan nilai tersebut relatif baik. Akurasi dosis serap juga dihitung berdasarkan nilai Root Mean Square Error (RMSE) untuk model STPD, 2TPD, 3TPD, Hänscheid dan didapatkan hasil secara berturut-turut sebesar 9,75; 6,25; 7,71; dan 8,11. Berdasarkan nilai tersebut, model STPD dapat diaplikasikan dan akurat untuk menentukan dosis serap pada pasien. | |
| dc.identifier.uri | https://ailib.my.id/handle/123456789/73087 | |
| dc.language.iso | id | |
| dc.publisher | Universitas Andalas | |
| dc.subject | Dosis serap | |
| dc.subject | Bayesian | |
| dc.subject | TIAC | |
| dc.subject | 177Lu-DOTATATE | |
| dc.subject.classification | QC Physics | |
| dc.title | PENENTUAN TINGKAT AKURASI DOSIMETRI BERBASIS DATA TUNGGAL PADA TERAPI 177Lu-DOTATATE MENGGUNAKAN PENCITRAAN SPECT/CT DAN FITTING BAYESIAN | |
| dc.type | Thesis | |
| dcterms.dateSubmitted | 2023-11-14 | |
| dcterms.references | [1] C. Maaß, J. P. Sachs, D. Hardiansyah, F. M. Mottaghy, P. Kletting, and G. Glatting, “Dependence of treatment planning accuracy in peptide receptor radionuclide therapy on the sampling schedule,” EJNMMI Res., vol. 6, no. 1, pp. 1–9, 2016. [2] W. E. Bolch, K. F. Eckerman, G. Sgouros, and S. R. Thomas, “MIRD pamphlet no. 21: a generalized schema for radiopharmaceutical dosimetry—standardization of nomenclature,” J. Nucl. Med., vol. 50, no. 3, pp. 477–484, 2009. [3] D. Hardiansyah et al., “The role of patient-based treatment planning in peptide receptor radionuclide therapy,” Eur. J. Nucl. Med. Mol. Imaging, vol. 43, no. 5, pp. 871–880, 2016. [4] A. R. Haug, “PRRT of neuroendocrine tumors: individualized dosimetry or fixed dose scheme?,” EJNMMI Res., vol. 10, no. 1, pp. 1–3, 2020. [5] J. A. Siegel et al., “MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates,” J. Nucl. Med., vol. 40, no. 2, pp. 37S-61S, 1999. [6] H. Hänscheid, C. Lapa, A. K. Buck, M. Lassmann, and R. A. Werner, “Dose mapping after endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a single measurement after 4 days,” J. Nucl. Med., vol. 59, no. 1, pp. 75–81, 2018. [7] M. Miederer, H. Reber, A. Helisch, C. Fottner, M. Weber, and M. Schreckenberger, “One single-time-point kidney uptake from OctreoScan correlates with number of desintegrations measured over 72 hours and calculated for the 6.7 hours half-life nuclide 177Lu,” Clin. Nucl. Med., vol. 37, no. 10, pp. e245–e248, 2012. [8] J. Gustafsson and J. Taprogge, “Theoretical aspects on the use of single-time-point dosimetry for radionuclide therapy,” Phys. Med. Biol., vol. 67, no. 2, p. 25003, 2022. [9] X. Hou et al., “Feasibility of single-time-point dosimetry for radiopharmaceutical therapies,” J. Nucl. Med., vol. 62, no. 7, pp. 1006–1011, 2021. [10] J. I. Gear et al., “EANM practical guidance on uncertainty analysis for molecular radiotherapy absorbed dose calculations,” Eur. J. Nucl. Med. Mol. Imaging, vol. 45, no. 13, pp. 2456–2474, 2018. [11] G. Glatting, P. Kletting, S. N. Reske, K. Hohl, and C. Ring, “Choosing the optimal fit function: Comparison of the Akaike information criterion and the F-test,” Med. Phys., vol. 34, no. 11, pp. 4285–4292, 2007, doi: 10.1118/1.2794176. [12] M. Gotthardt et al., “Indication for different mechanisms of kidney uptake of radiolabeled peptides,” J. Nucl. Med., vol. 48, no. 4, pp. 596–601, 2007. [13] J. Thundimadathil, “Cancer treatment using peptides: current therapies and future prospects,” J. Amino Acids, vol. 2012, 2012. [14] S. R. Cherry, J. A. Sorenson, and M. E. Phelps, Physics in nuclear medicine e-Book. Elsevier Health Sciences, 2012. [15] G. Glatting, M. Bardiès, and M. Lassmann, “Treatment planning in molecular radiotherapy,” Z. Med. Phys., vol. 23, no. 4, pp. 262–269, 2013. [16] P. Vicini, A. B. Brill, M. G. Stabin, and A. Rescigno, “Kinetic modeling in support of radionuclide dose assessment,” in Seminars in nuclear medicine, 2008, vol. 38, no. 5, pp. 335–346. [17] L. D. Marinelli, J. B. Trunnell, R. F. Hill, and F. W. Foote, “Factors Involved in the Experimental Therapy of Metastatic Thyroid Cancer with I131: A Preliminary Report,” Radiology, vol. 51, no. 4, pp. 553–557, 1948. [18] L. D. Jiménez-Franco, G. Glatting, V. Prasad, W. A. Weber, A. J. Beer, and P. Kletting, “Effect of tumor perfusion and receptor density on tumor control probability in 177Lu-DOTATATE therapy: An in silico analysis for standard and optimized treatment,” J. Nucl. Med., vol. 62, no. 1, pp. 92–98, 2021, doi: 10.2967/jnumed.120.245068. [19] As. Kopp, “INDEX OF WORLD PHARMACOPOEIAS and PHARMACOPOEIAL AUTHORITIES The Index of World Pharmacopoeias and Pharmacopoeial Authorities has been circulated to national and regional Table of contents,” no. May, 2019. [20] R. R. ISLAMIATY and E. L. I. HALIMAH, “Tinjauan Pustaka Mengenai Karakteristik Radioisotop yang Digunakan pada Pembuatan Radiofarmaka,” Farmaka, vol. 16, no. 1, pp. 222–230, 2018. [21] F. A. Mettler and M. J. Guiberteau, Essentials of Nuclear Medicine and Molecular Imaging E-Book. Elsevier Health Sciences, 2018. [22] T. U. S. Food and T. U. S. Food, “FDA approves new treatment for certain digestive tract cancers | FDA,” pp. 2–3, 2018, [Online]. Available: https://www.fda.gov/news-events/press-announcements/fda-approves-new-treatment-certain-digestive-tract-cancers. [23] B. L. R. Kam et al., “Lutetium-labelled peptides for therapy of neuroendocrine tumours,” Eur. J. Nucl. Med. Mol. Imaging, vol. 39, no. 1, pp. 103–112, 2012. [24] J.-P. Esser et al., “Comparison of [177Lu-DOTA0, Tyr3] octreotate and [177Lu-DOTA0, Tyr3] octreotide: which peptide is preferable for PRRT?,” Eur. J. Nucl. Med. Mol. Imaging, vol. 33, no. 11, pp. 1346–1351, 2006. [25] P. Kletting et al., “Molecular radiotherapy: the NUKFIT software for calculating the time‐integrated activity coefficient,” Med. Phys., vol. 40, no. 10, p. 102504, 2013. [26] M. E. Glickman and D. A. van Dyk, “Basic bayesian methods,” Top. Biostat., pp. 319–338, 2007. [27] P. Kletting and G. Glatting, “Model selection for time-activity curves: The corrected Akaike,” Z. Med. Phys., vol. 19, no. 3, pp. 200–206, 2009. [28] T. P. Devasia, Y. K. Dewaraja, K. A. Frey, K. K. Wong, and M. J. Schipper, “A Novel Time-Activity Information-Sharing Approach Using Nonlinear Mixed Models for Patient-Specific Dosimetry with Reduced Imaging Time Points: Application in SPECT/CT After 177Lu-DOTATATE,” J. Nucl. Med., vol. 62, no. 8, pp. 1118–1125, 2021, doi: 10.2967/jnumed.120.256255. [29] “Pembuatan Radioisotop Lutesium.” . [30] D. Hardiansyah, A. Riana, A. J. Beer, and G. Glatting, “Single-time-point estimation of absorbed doses in PRRT using a non-linear mixed-effects model,” Zeitschrift fuer Medizinische Phys., 2022, doi: 10.1016/j.zemedi.2022.06.004. | |
| local.eprints.dir | disk0/00/45/74/51 | |
| local.eprints.division | S2 | |
| local.eprints.id | 457451 | |
| local.eprints.type | thesis/masters | |
| local.eprints.uri | http://scholar.unand.ac.id/457451/ | |
| local.fakultas | Pascasarjana (S2) | |
| local.identifier.nim | 2120441003 | |
| local.thesis.level | Tesis |