PENENTUAN CONFINED AQUIFER DENGAN MENGGUNAKAN METODE GEOLISTRIK UNTUK PENGEBORAN AIR TANAH DALAM DI UNIVERSITAS NEGERI PADANG
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Universitas Andalas
Abstract
ABSTRACT
The problem that arises with the development of UNP is the need for large amounts
of clean water. From the analysis results, the need for clean water to serve all
activities at UNP is 550 m
/day or the equivalent of 6.4 liters/second. On the other
hand, the available water sources are inadequate in quantity and quality to serve all
existing activities and facilities. Therefore, a new water source is needed that comes
from deep ground water or water located in the confined aquifer zone. To determine
the existence and condition of groundwater, an initial investigation was carried out
using the geoelectric survey method and prepared a drilling plan and prepared a
cost budget. From the results of investigations, geologically, hydrogeologically and
in correlation between lithologies, it was found that the confined aquifer system at
UNP is divided into three systems, namely: Confined aquifer system I (10 – 45 m)
in the East-South and North parts continuing to the West. Aquifer System II (55 –
130 m) in almost the entire UNP area, and Aquifer System III (70 – 130 m) in the
western part. To obtain a water discharge of 6.4 liters/second, drilling can be carried
out to a depth of 250 m with a diameter of 10 inches and a submersible pump
diameter of 6 inches. The costs required are Rp. 1,519,672,550,-
3
Keywords: Confined, Unconfined Aquifer, Aquifer System, Geoelectric, and
Submersible Pump
Description
Prof. Dr. Ir. James Hellyward, MS, IPU, ASEAN Eng