UPT Perpustakaan Universitas Andalas
Repositori PerpustakaanUniversitas Andalas
 

Finite Element Analysis of Strength and Stiffness of Injured and Implanted Thoracolumbar

dc.contributor.advisorMeifal, Rusli
dc.contributor.authorAdnan, Hanif
dc.date.accessioned2026-09-24T21:23:05Z
dc.date.issued2024-02-02
dc.descriptionMeifal Rusli
dc.description.abstractThoracolumbar is the most often fractured part in the spine. Thoracolumbar fracture results from several axial loading of the spine usually due to fall, vehicle accident, etc. Thoracolumbar fracture can lead to some serious injuries like significant disability, deformity and neurological deficit. Posterior instrumentation with pedicle screw and rods had been the most used method for surgical stabilization. Surgical treatment of thoracolumbar fracture was aimed to decompress the neural tissue, stabilize the columns, which requires rigid fixation. Spinal instrumentation has recent advances over the years and today’s spinal surgeon is well equipped to rigidly fix the spine with the complex cases. Normal, injured and implanted thoracolumbar are modelled in 3D design software and imported to MSC Marc Mentat to simulate with 500 N compressional load and 7.5 N.m moment to analyze the strength and stiffness of the models with comparing the displacement and the von Mises stress in the simulation. There were some significant differences between the displacement of normal, injured and implanted thoracolumbar. The displacement of thoracolumbar increases after injury and make it more unstable, and after implanting the implant, the displacement is decrease and make thoracolumbar more rigid. The von Mises stress of injured thoracolumbar is higher than normal thoracolumbar which high stress happened in fracture L1. After adding the implant, the von Mises stress reduce at fracture L1. Implanting the implant makes the stress higher at the implant especially in pedicle screw
dc.identifier.urihttps://ailib.my.id/handle/123456789/49479
dc.language.isoid
dc.publisherUniversitas Andalas
dc.subjectThoracolumbar
dc.subjectFracture
dc.subjectSpinal Implant
dc.subjectBiomechanics
dc.subjectFinite Element Analysis
dc.subject.classificationTJ Mechanical engineering and machinery
dc.titleFinite Element Analysis of Strength and Stiffness of Injured and Implanted Thoracolumbar
dc.typeThesis
dcterms.dateSubmitted2024-02-06
dcterms.references[1] H. Wang et al., “Epidemiology of traumatic spinal fractures: Experience from medical university-affiliated hospitals in Chongqing, China,2001-2010:Clinical article,” J. Neurosurg. Spine, vol. 17, no. 5, pp. 459–468, 2012, doi: 10.3171/2012.8.SPINE111003. [2] W. P. Shuman, J. V. Rogers, and M. E. Sickler, “Thoracolumbar burst fractures: CT dimensions of the spinal canal relative to postsurgical improvement,” Am. J. Neuroradiol., vol. 6, no. 3, pp. 337–341, 1985, doi: 10.2214/ajr.145.2.337. [3] S. Rajasekaran, R. M. Kanna, and A. P. Shetty, “Management of thoracolumbar spine trauma An overview,” Indian J. Orthop., vol. 49, no. 1, pp. 72–82, 2015, doi: 10.4103/0019-5413.143914. [4] K. Alpantaki et al., “Thoracolumbar burst fractures: A systematic review of management,” Orthopedics, vol. 33, no. 6, pp. 422–429, 2010, doi: 10.3928/01477447-20100429-24. [5] T. Okamoto, M. Neo, S. Fujibayashi, H. Ito, M. Takemoto, and T. Nakamura, “Mechanical implant failure in posterior cervical spine fusion,” Eur. Spine J., vol. 21, no. 2, pp. 328–334, 2012, doi: 10.1007/s00586-011-2043-8. [6] A. Soroceanu et al., “Radiographical and Implant-Related Complications in Adult Spinal Deformity Surgery: Incidence, Patient Risk Factors, and Impact on Health-Related Quality of Life.,” Spine (Phila. Pa. 1976)., vol. 40, no. 18, pp. 1414–1421, Sep. 2015, doi: 10.1097/BRS.0000000000001020. [7] A. Gupta, K. Das, K. Bansal, H. Singh Chhabra, and M. Arora, “Should Implant Breakage Be Always Considered as Implant ‘Failure’ in Spine Surgery: Analysis of Two Cases and Literature Review,” Cureus, vol. 13, no. 5, pp. 1–11, 2021, doi: 10.7759/cureus.15233. [8] Y.-H. Kang, “Anatomy and Physiology of Lumbar Spine,” J. Korean Soc. Spine Surg., vol. 8, no. 3, p. 264, 2001, doi: 10.4184/jkss.2001.8.3.264. [9] B. M. Boszczyk, A. A. Boszczyk, and R. Putz, “Comparative and functional anatomy of the mammalian lumbar spine.,” Anat. Rec., vol. 264, no. 2, pp. 157–168, Oct. 2001, doi: 10.1002/ar.1156. [10] N. Bogduk, “Clinical Anatomy of the Lumbar Spine and Sacrum,” 1997. [Online]. Available: https://api.semanticscholar.org/CorpusID:70636323 [11] A. M. R. Agur, M. J. Lee, and J. C. B. Grant, Grant’s atlas of anatomy, 10th ed. Philadelphia SE - xvi, 760 pages : color illustrations ; 28 cm: Lippincott Williams & Wilkins Philadelphia, 1999. doi: LK - https://worldcat.org/title/41049668. [12] S. J. Edmondston and K. P. Singer, “Thoracic spine: anatomical and biomechanical considerations for manual therapy.,” Man. Ther., vol. 2, no. 3, pp. 132–143, Aug. 1997, doi: 10.1054/math.1997.0293. [13] A. A. 3rd White, “Analysis of the mechanics of the thoracic spine in man. An experimental study of autopsy specimens.,” Acta Orthop. Scand. Suppl., vol. 127, pp. 1–105, 1969, doi: 10.3109/ort.1969.40.suppl-127.01. [14] S. Goh et al., “Influence of age and gender on thoracic vertebral body shape and disc degeneration: an MR investigation of 169 cases.,” J. Anat., vol. 197 Pt 4, no. Pt 4, pp. 647–657, Nov. 2000, doi: 10.1046/j.1469-7580.2000.19740647.x. [15] C. Liebsch and H.-J. Wilke, “Chapter 3 - Basic Biomechanics of the Thoracic Spine and Rib Cage,” in Biomechanics of the Spine, F. Galbusera and H.-J. Wilke, Eds., Academic Press, 2018, pp. 35–50. doi: https://doi.org/10.1016/B978-0-12-812851-0.00003-3. [16] R. M. Kanna, D. C. Raja, A. P. Shetty, and S. Rajasekaran, “Thoracolumbar Fracture Dislocations Without Spinal Cord Injury: Classification and Principles of Management,” Glob. Spine J., vol. 11, no. 1, pp. 63–70, Nov. 2019, doi: 10.1177/2192568219890568. [17] M. Q. Azam and M. Sadat-Ali, “The Concept of Evolution of Thoracolumbar Fracture Classifications Helps in Surgical Decisions.,” Asian Spine J., vol. 9, no. 6, pp. 984–994, Dec. 2015, doi: 10.4184/asj.2015.9.6.984. [18] R. WATSON-JONES, “THE RESULTS OF POSTURAL REDUCTION OF FRACTURES OF THE SPINE,” JBJS, vol. 20, no. 3, 1938, [Online]. Available: https://journals.lww.com/jbjsjournal/fulltext/1938/20030/the_results_of_postural_reduction_of_fractures_of.2.aspx [19] E. A. Nicoll, “Fractures of the dorso-lumbar spine,” J. Bone Joint Surg. Br., vol. 31, no. 3, pp. 376–394, 1949. [20] S. D. Gertzbein, “Scoliosis Research Society. Multicenter spine fracture study.,” Spine (Phila. Pa. 1976)., vol. 17, no. 5, pp. 528–540, 1992. [21] K. Omran, H. A. Ali, A. Saleh, A. Omar, I. Elhawery, and A. Z. A. Alkhooly, “One Stage Anterior Reconstruction and Posterior Instrumentation in Surgical Management of Thoracolumbar Spine Fractures,” Open J. Orthop., vol. 05, pp. 6–15, 2015, [Online]. Available: https://api.semanticscholar.org/CorpusID:6036818 [22] A. Warburton, S. J. Girdler, C. M. Mikhail, A. Ahn, and S. K. Cho, “Biomaterials in spinal implants: A review,” Neurospine, vol. 17, no. 1, pp. 101–110, 2020, doi: 10.14245/ns.1938296.148. [23] V. K. Meena, P. Kumar, P. Kalra, and R. K. Sinha, “Additive manufacturing for metallic spinal implants: A systematic review,” Ann. 3D Print. Med., vol. 3, p. 100021, 2021, doi: 10.1016/j.stlm.2021.100021. [24] W. Davis et al., “Modern spinal instrumentation . Part 1 : Normal spinal implants,” Clin. Radiol., vol. 68, no. 1, pp. 64–74, 2013, doi: 10.1016/j.crad.2012.05.001. [25] P. J. Rao, M. H. Pelletier, W. R. Walsh, and R. J. Mobbs, “Spine Interbody Implants: Material Selection and Modification, Functionalization and Bioactivation of Surfaces to Improve Osseointegration,” Orthop. Surg., vol. 6, no. 2, pp. 81–89, 2014, doi: 10.1111/os.12098. [26] B. A. Kornah, F. H. Zayed, and A. K. A. Elkomy, “Review of Spinal Pedicle Screws,” Egypt. J. Hosp. Med., vol. 76, no. 6, pp. 4307–4311, 2019, doi: 10.21608/ejhm.2019.43812. [27] W. Cho, S. K. Cho, and C. Wu, “The biomechanics of pedicle screw-based instrumentation,” J. Bone Jt. Surg. Br. Vol., vol. 92, no. 8, pp. 1061–1065, 2010. [28] D. King, “Internal fixation for lumbosacral fusion,” JBJS, vol. 30, no. 3, pp. 560–578, 1948. [29] H. PR, “Reduction of severe spondylolisthesis in children,” South Med J, vol. 62, pp. 1–7, 1969. [30] H. H. Boucher, “A method of spinal fusion,” J. Bone Joint Surg. Br., vol. 41, no. 2, pp. 248–259, 1959. [31] R. W. Gaines, “Current Concepts Review The Use of Pedicle-Screw Internal Fixation for the Operative Treatment of Spinal Disorders *,” JBJS-Am, vol. 82-A, no. 10, pp. 1458–1476, 1984. [32] H. Yoshihara, “Rods in spinal surgery: A review of the literature,” Spine J., vol. 13, no. 10, pp. 1350–1358, 2013, doi: 10.1016/j.spinee.2013.04.022. [33] T. B. Hunter, M. T. Yoshino, R. B. Dzioba, R. A. Light, and W. G. Berger, “Medical devices of the head, neck, and spine,” Radiographics, vol. 24, no. 1, pp. 257–285, 2004. [34] W. Lehmann, D. Briem, M. Blauth, and U. Schmidt, “Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems,” Eur. Spine J., vol. 14, no. 3, pp. 243–249, 2005, doi: 10.1007/s00586-004-0746-9. [35] T.Y. Yang, Finite element Structural Analysis. Prentice-Hall, 1986. [36] A. K. Roth et al., “Validation of a finite element model of the thoracolumbar spine to study instrumentation level variations in early onset scoliosis correction,” J. Mech. Behav. Biomed. Mater., vol. 117, no. February, p. 104360, 2021, doi: 10.1016/j.jmbbm.2021.104360. [37] J. P. Wang et al., “Finite element analysis of the spondylolysis in lumbar spine,” Biomed. Mater. Eng., vol. 16, no. 5, pp. 301–308, 2006. [38] C. Veiga, J. P. Davim, and A. Loureiro, “Properties and applications of titanium alloys : A brief review PROPERTIES AND APPLICATIONS OF TITANIUM ALLOYS : A BRIEF REVIEW,” no. July 2016, 2012. [39] W. Schmoelz, K. D. Schaser, C. Knop, M. Blauth, and A. C. Disch, “Extent of corpectomy determines primary stability following isolated anterior reconstruction in a thoracolumbar fracture model.,” Clin. Biomech. (Bristol, Avon), vol. 25, no. 1, pp. 16–20, Jan. 2010, doi: 10.1016/j.clinbiomech.2009.09.010. [40] H. Lu, Q. Zhang, F. Ding, Q. Wu, and R. Liu, “Establishment and validation of a T12-L2 3D finite element model for thoracolumbar segments.,” Am. J. Transl. Res., vol. 14, no. 3, pp. 1606–1615, 2022.
local.eprints.dirdisk0/00/46/18/37
local.eprints.division07E
local.eprints.id461837
local.eprints.typethesis/diploma
local.eprints.urihttp://scholar.unand.ac.id/461837/
local.fakultasFakultas Teknik
local.identifier.nim1710912042
local.prodiS1 Teknik Mesin
local.thesis.levelSkripsi

Files

Collections